At this time, no studies have investigated the effect of mandibul

At this time, no studies have investigated the effect of mandibular flexure on long-span, unilateral, implant fixed prostheses. The clinical significance of mandibular flexure on the success

of dental implant treatment is at this time unclear, and further research is PD0325901 purchase needed. “
“Purpose: Marginal adaptation is an important factor affecting the longevity of all-ceramic restorations, although the effects of different fabrication steps on marginal adaptation at various stages of fabrication are not fully understood. The purpose of this study was to assess with an in vitro model whether In-Ceram alumina (IA) or In-Ceram zirconia (IZ) copings produced by the CAD/CAM method would be clinically acceptable, and to evaluate

the effect of each fabrication step (post-milling, post-trimming, and post-glass infiltration) on the marginal discrepancy of the coping. Materials and Methods: A melamine tooth was prepared, duplicated, poured with inlay wax, and then cast with metal to fabricate a master die. An InLab 3D system was used to scan the master die and to design and mill the copings. Thirty IA and IZ copings each were developed with thicknesses of 0.6 mm and a 30-μm thick computer luting space. Epoxy resin replicas of the master die were fabricated, and the vertical and horizontal marginal discrepancies were measured learn more using a Micro-Vu optical microscope at three stages of the fabrication (post-milling, post-trimming, post-infiltration). One-way ANOVA was used to analyze the data between the three stages of fabrication for each marginal discrepancy, and a t-test was used to compare vertical and horizontal marginal discrepancies

(after glass infiltration) between IZ and IA copings Results: There were no significant differences (p > 0.05) in the vertical marginal discrepancies (μm) between IA (36 ± 14) and IZ (40 ± 14) copings after glass infiltration. ANOVA (comparing three stages within horizontal marginal discrepancy for IZ copings) showed that post-milling (40 ± 26) > post-trimming (23 ± 11) = post-infiltration (19 ± 13). ANOVA (comparing three stages within vertical marginal discrepancy for IZ copings) showed that post-milling (53 ± 12) = post-trimming (47 ± 13) > post-infiltration MCE公司 (36 ± 14). ANOVA (comparing three stages within horizontal marginal discrepancy for IA copings) showed that post-milling (52 ± 28) > post-trimming (30 ± 16) > post-infiltration (30 ± 16). ANOVA (comparing three stages within vertical marginal discrepancy for IA copings) showed that post-milling (54 ± 13) = post-trimming (56 ± 26) > post-infiltration (40 ± 14). Conclusion: There was no significant difference in the marginal adaptation of both material copings. After the trimming process, the glass infiltration firing cycle improved the vertical marginal discrepancy for both IZ and IA copings. Clinical implications.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>