They were identified by presurgical or routine laboratory screening. None of them showed bleeding. Three different mutations were detected (Glu117Stop, Cys118Arg and Trp497Gly); two of them were novel (Cys118Arg and Trp497Gly). One patient (with severe FXI levels) showed a compound heterozygosity (Glu117Stop with Cys118Arg). Two novel missense mutations were highly conserved among different
species. In our patients, bleeding tendency did not appear to be correlated PD-0332991 price with FXI levels or with a single mutation in heterozygosis. On the other hand, the compound heterozygosis might explain low FXI levels, but it is not associated with bleeding. Our data confirm that a severe FXI deficiency is not necessarily associated with bleeding. “
“Summary. Up to 40% of patients with mild haemophilia A have a discrepancy whereby factor VIII (FVIII) measurements by a two-stage chromogenic assay (FVIII:CCH) are disproportionately reduced compared with the FVIII one-stage
clotting value (FVIII:C). Which assay best reflects the coagulation potential and clinical phenotype in this patient group is of clinical significance, yet remains unclear. We have assessed the global coagulant ability of haemophilia patients with FVIII assay discrepancy using calibrated automated thrombography (CAT). A total of 18 patients with mutations Arg531His/Cys or Arg698Trp causing Inhibitor Library clinical trial FVIII discrepancy were investigated, together with 12 haemophilia patients with concordant FVIII MCE values and 15 normal controls. Factor VIII levels in all patients and controls were measured using both one-stage clotting assay and two-stage chromogenic assay. Thrombin generation was assessed in platelet-poor plasma by CAT using a low tissue factor concentration (1 pm). FVIII:CCH values were below normal in all patients, and in the discrepant group were between 1.5- and 8-fold lower than FVIII:C values. CAT parameters were affected in all haemophilia patients. The endogenous thrombin potential (ETP) was reduced to 58–67% of the mean normal value (1301 nm min−1),
whereas peak thrombin was further reduced to 27–30% of the mean normal value (178 nm) in both discrepant and concordant patient groups. Analysis of the discrepant patient group showed the most significant correlation between the one-stage FVIII:C assay and ETP (r2 = 0.44) and peak thrombin parameters (r2 = 0.27). “
“Approximately 30% of patients with hemophilia A (HA) and 3% with hemophilia B (HB) develop inhibitory antibodies to factors VIII or IX, respectively, as a complication of replacement therapy. The strongest identified determinant of inhibitor development risk is the mutation type in the F8 or F9 gene. Large deletions, nonsense mutations and inversions are associated with a high risk of inhibitor development ranging from 20 to 75%. In non-severe haemophilia patients, missense mutations represent the main mutation type, with an inhibitor prevalence of 5%, conferring a low risk.