Batch mode SEOP, as a potential low cost alternative, is being fu

Batch mode SEOP, as a potential low cost alternative, is being further developed using

various approaches by other groups [30] and [31]. For example high noble gas concentration at low pressures in batch mode SEOP has been recently explored to bypass the need for cryogenic separation [31]. This selleck inhibitor method produced the equivalent of hp 129Xe gas with Php = 14% at a rate of 1.8 cm3/min using only 23 W of laser power. For hp 83Kr, where cryogenic separation is not feasible due to rapid quadrupolar relaxation in the frozen state, the method allowed for Php = 3% at a rate of 2.0 cm3/min. For very specialized applications, it is also possible to hyperpolarize 129Xe together with a reactive gas. This has been demonstrated in SEOP of CH4–Xe mixtures that served as fuel for hp 129Xe MRI of combustion [37]. Methane as a saturated hydrocarbon compound shows little affinity to react with rubidium under SEOP conditions. The polarization obtained in a 5% Xe, 10% N2, and 85% CH4 mixture was Php = 7% in continuous

flow mode at 40 cm3/min and Php = 40% in batch mode SEOP. One crucial element in the improvements of SEOP systems are the many advances made in solid-state laser technology. Line-narrowed laser output at growing power levels becomes increasingly available and affordable [38]. Furthermore, an alternative methodology of potential interest for hp noble gas MRI has recently been explored. Dynamic nuclear polarization (DNP) selleck screening library at 1.2 K was reported as a new approach to generate hp 129Xe state at potentially high volumes [39]. Whatever methodology will ultimately be the most successful, the proliferation of techniques to conveniently and inexpensively polarize noble gases appears likely. One should therefore expect for hp noble gas MRI to move beyond its current usage limited to highly specialized research facilities. Possibly the most useful applications of simple spin density gas phase imaging of hp noble gases are in lung functional studies. The clinically most relevant parameter that can be garnered from static Epothilone B (EPO906, Patupilone) pulmonary ventilation

scans are ventilation defects [40]. In patients with chronic obstructive pulmonary disease (COPD) or asthma it is possible to monitor the evolution of these defects as the diseases progress over time during clinical, longitudinal studies. It is also possible to observe the response to airway hyperresponsiveness tests in asthma [41]. Effective ventilation deduced by hp MRI in vivo has been shown to correlate with spirometry data for patients in health and disease [40] and [42]. However, although the hp noble gas ventilation images may appear dramatic when displaying larger unventilated areas in lungs it should be noted that this might not be necessarily specific to one disease pathology, rather they reveal the extent and severity of ventilation defects that may be common in many conditions ( Fig. 2, [43]). Safe in vivo delivery of hp noble gases merits special mentioning.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>